5KV, 90 MIL XLP/PVC 100/133%, W/S (1/C)

SKU: 008

5kV or 5kVU Type MV-90. Copper Conductor. Thermosetting Conductor Shield. Cross-linked Polyethylene (XLP) Insulation. Thermosetting Insulation Shield. Copper Wire Shield. PVC Jacket.

 

APPLICATIONS

Southwire 07XW Type MV- 90 Cable is for use in aerial, direct burial, conduit, and underground duct installations as permitted by the National Electrical Code. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000V, 100% (grounded system) and 133% insulation level (ungrounded system).

SPECIFICATIONS

Southwire 07XW Type MV-90 Cable is manufactured and tested in accordance with the latest revisions of the following standards and specification:

  • UL 1072 – Medium Voltage Power Cables.
  • ICEA S-93-639 (NEMA WC 74) – 5-46 kV Shielded Power Cable for Use in the Transmission & Distribution of Electric Energy.

Certified qualification tests were performed in accordance with the requirements of AEIC CS-8. Cable has fully met the qualification testing requirements of AEIC CS-8.

 

CONSTRUCTION

Southwire 07XW Type MV- 90 Cable offers proven XLP insulation, 90°C continuous conductor operating temperature, fast stripping thermosetting insulation shield, and it is triple extruded. Cable is sunlight resistant, suitable for direct burial. SOLONON™ low smoke, non halogen polyolefin jackets are available upon request.

 

07XW 1c, 5kV, 90mil XLP(100/133%), WS, PVC

Scope: This specification covers single conductor XLP (cross-linked thermosetting polyethylene) insulated, shielded, thermoplastic jacketed power cable for use in aerial, direct burial, conduit, and underground duct installations. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions, and are rated at 5,000 volts, 100% and 133% insulation level.

Standards: The following standards shall form a part of this specification – UL Standard 1072 for Medium Voltage Power Cable and ICEA S-93-639 (NEMA WC 74) 5-46 kV Shielded Power Cable for Use in the Transmission & Distribution of Electric Energy.

Conductor: The conductor shall be Class B compressed concentric stranded bare copper in accordance with ASTM specs B3 and B8 and ICEA Part 2, Section 2.1 and 2.5.

Conductor Shield: The conductor shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be firmly bonded to the insulation. The thickness shall be in accordance with the referenced standards.

Insulation: The insulation shall be XLP meeting the requirements of the referenced standards. The nominal thickness shall be 0.090″.

Insulation Shield: The insulation shall be shielded with an extruded semi-conducting thermosetting polymeric layer which shall be identified as semi-conducting. The thickness shall be in accordance with the referenced standards. Over this layer shall be applied a concentric serve of #24 AWG annealed solid bare copper wires over which shall be applied a lapped non-metallic tape.

Jacket: The cable shall be covered with a black sunlight resistant PVC jacket conforming to the requirements specified for polyvinyl chloride jackets in ICEA. The average thickness shall be in accordance with Table 7-3 of ICEA. Optional SOLONON low smoke, non halogen polyolefin jackets are available upon request.

Identification: Cable shall be identified by surface printing on the jacket.

Tests: Qualification tests shall be conducted in accordance with the requirements AEIC.

DON'T SEE WHAT YOU'RE LOOKING FOR?

sales@prolinesafety.com

(630) 876-1050

Pro-Line Safety Products Co. 1099 Atlantic Drive, Unit #1 West Chicago, IL 60185

Become A Distributor

We’re looking for qualified companies to join our distributor team!

©2022 Trident Solutions. All rights reserved. We are an equal opportunity employer and are dedicated to hiring qualified candidates.